1
00:00:00,100 --> 00:00:04,380
Record a failed or passed readiness check
Save what was observed on the

2
00:00:04,380 --> 00:00:08,025
exact tagged item before making it
available for issue

3
00:00:08,125 --> 00:00:12,660
Step 1 In Site operations select Refresh
records

4
00:00:12,660 --> 00:00:17,355
and go to Readiness Use Filter by tag
serial or manifest

5
00:00:17,355 --> 00:00:20,960
to narrow the list then select the item in
Equipment and compare the

6
00:00:20,960 --> 00:00:25,850
displayed identifiers and pool You should
see The item details

7
00:00:25,850 --> 00:00:30,625
match the equipment being checked
Selecting a radio shows Observed radio

8
00:00:30,625 --> 00:00:35,140
battery % a separately tracked battery has
no percentage field

9
00:00:35,140 --> 00:00:36,230
here

10
00:00:36,330 --> 00:00:40,935
Step 2 Choose Checked condition Good Fair
Poor

11
00:00:40,935 --> 00:00:45,625
or Damaged For a radio enter the observed
battery percentage from 0

12
00:00:45,625 --> 00:00:50,190
to 100 Choose Did not pass or Passed in
Observed check result

13
00:00:50,190 --> 00:00:54,700
according to the inspection A charged
radio can still fail because it

14
00:00:54,700 --> 00:01:00,775
is damaged You should see Condition and
outcome are separate observations

15
00:01:00,775 --> 00:01:03,475
Not checked is not a readiness result

16
00:01:03,575 --> 00:01:08,320
Step 3 Select Save readiness check and
wait for the result notice before

17
00:01:08,320 --> 00:01:13,010
checking another item You should see
Readiness check recorded confirms

18
00:01:13,010 --> 00:01:16,980
the save A failed item must not be issued

19
00:01:17,080 --> 00:01:21,795
Check the result For the same tag use Find
at Equipment desk

20
00:01:21,795 --> 00:01:26,520
where authorised to review the resulting
status A passing check does not

21
00:01:26,520 --> 00:01:29,945
clear a fault or override another issue
restriction

22
00:01:30,045 --> 00:01:34,300
If something goes wrong The submission is
unresolved or the item is

23
00:01:34,300 --> 00:01:39,150
missing For unresolved work keep the tab
and use Retry pending submission

24
00:01:39,150 --> 00:01:44,295
unchanged Refresh records can inspect but
does not clear it

25
00:01:44,295 --> 00:01:48,935
After a conflict refresh and reselect the
item If the item is

26
00:01:48,935 --> 00:01:54,010
absent check the filter tag site and pool
before proceeding

27
00:01:54,183 --> 00:01:58,668
Record a fault and mark it In repair Make
the defect visible to the team

28
00:01:58,668 --> 00:02:01,118
and show when repair is under way

29
00:02:01,218 --> 00:02:06,608
Step 1 In Browser fleet select Faults and
service

30
00:02:06,608 --> 00:02:11,133
Expand New fault select Fault radio by tag
enter a specific

31
00:02:11,133 --> 00:02:15,913
Fault type such as Cracked case and choose
Severity Low Medium

32
00:02:15,913 --> 00:02:20,428
or High Select Record fault You should see

33
00:02:20,428 --> 00:02:25,048
Under the radio in Maintenance register
Faults shows the type severity and

34
00:02:25,048 --> 00:02:26,688
open status

35
00:02:26,788 --> 00:02:31,323
Step 2 When the equipment goes into repair
find that fault

36
00:02:31,323 --> 00:02:35,933
under the correct radio In New fault
status choose In repair then

37
00:02:35,933 --> 00:02:40,493
select Save fault status You should see
The register shows the

38
00:02:40,493 --> 00:02:45,458
fault in repair The register line may
display the status as repair

39
00:02:45,458 --> 00:02:49,023
Workspace’s Checks and faults displays In
repair

40
00:02:49,123 --> 00:02:53,583
Check the result Match the radio tag and
fault text on the refreshed

41
00:02:53,583 --> 00:02:58,538
register The unresolved fault is a reason
to keep the unit out of issue

42
00:02:58,538 --> 00:03:00,438
not a service booking

43
00:03:00,538 --> 00:03:04,988
If something goes wrong The fault is not
shown or the status choice is

44
00:03:04,988 --> 00:03:09,708
absent Use Refresh server snapshot to
check the pool and read the latest

45
00:03:09,708 --> 00:03:14,808
status it may already be in repair For an
unresolved save

46
00:03:14,808 --> 00:03:19,588
use Retry saved request from the original
tab If saving is disabled

47
00:03:19,588 --> 00:03:24,088
because the tab cannot store requests
safely keep the tab and seek support

48
00:03:24,088 --> 00:03:26,438
rather than clearing site data

49
00:03:26,600 --> 00:03:31,190
Schedule linked service and record
completion Keep the work due

50
00:03:31,190 --> 00:03:35,100
the linked fault and the work actually
done together in the register

51
00:03:35,200 --> 00:03:40,045
Step 1 Expand Schedule service then choose
Service radio

52
00:03:40,045 --> 00:03:44,635
and Service type Inspection Service or
Repair Enter

53
00:03:44,635 --> 00:03:48,915
Due date add Provider and Service notes as
appropriate and select the

54
00:03:48,915 --> 00:03:53,555
correct Linked fault optional for that
radio Select

55
00:03:53,555 --> 00:03:58,360
Schedule service You should see Under
Service the register

56
00:03:58,360 --> 00:04:02,395
shows a planned record with its due date
and any provider notes and fault

57
00:04:02,395 --> 00:04:04,125
link you supplied

58
00:04:04,225 --> 00:04:09,140
Step 2 When work is done find that planned
entry by radio

59
00:04:09,140 --> 00:04:13,925
type and due date Enter Completion date
and a non-blank Service result

60
00:04:13,925 --> 00:04:18,595
describing the work Select Complete
service You should

61
00:04:18,595 --> 00:04:23,745
see The record shows completed with the
completion date and result

62
00:04:23,745 --> 00:04:26,315
The linked fault is still unresolved

63
00:04:26,415 --> 00:04:31,070
Check the result Read the service and
fault lines together

64
00:04:31,070 --> 00:04:34,620
A completed repair leaves the radio
blocked until the separate readiness

65
00:04:34,620 --> 00:04:37,710
and fault resolution steps are satisfied

66
00:04:37,810 --> 00:04:42,750
If something goes wrong The fault is not
in the list or the page reports

67
00:04:42,750 --> 00:04:47,275
a conflict Linked fault optional lists
unresolved

68
00:04:47,275 --> 00:04:53,165
faults on the selected radio only Check
the radio and current fault status

69
00:04:53,165 --> 00:04:57,045
After a conflict refresh and inspect the
planned or completed record

70
00:04:57,045 --> 00:05:00,320
before deciding whether any further save
is needed

71
00:05:00,433 --> 00:05:04,973
Retest resolve the fault and review
history Tie resolution

72
00:05:04,973 --> 00:05:09,068
to the latest passing check and verify the
radio before reissue

73
00:05:09,168 --> 00:05:13,828
Step 1 After service inspect the radio and
follow Record

74
00:05:13,828 --> 00:05:17,893
a failed or passed readiness check Enter
the condition and battery

75
00:05:17,893 --> 00:05:22,683
percentage you actually observed and
record whether the check passed

76
00:05:22,683 --> 00:05:27,363
You should see The new readiness save is
confirmed A failed retest

77
00:05:27,363 --> 00:05:31,173
remains a failed result and is not grounds
for resolution

78
00:05:31,273 --> 00:05:36,023
Step 2 Return to Browser fleet Select
Refresh

79
00:05:36,023 --> 00:05:40,608
server snapshot and find the unresolved
fault Choose Resolved in New

80
00:05:40,608 --> 00:05:45,608
fault status then select Save fault status
You should see

81
00:05:45,608 --> 00:05:48,933
Resolved is offered only when the latest
readiness check is a recorded

82
00:05:48,933 --> 00:05:53,473
pass with an identifier The saved fault
line shows Readiness check and

83
00:05:53,473 --> 00:05:55,273
its identifier

84
00:05:55,373 --> 00:06:00,258
Step 3 Review the completed work in
Maintenance register

85
00:06:00,258 --> 00:06:04,838
In Workspace open the tag in Equipment and
read Fault history

86
00:06:04,838 --> 00:06:09,978
Use Find at Equipment desk to check status
before reissue You should see

87
00:06:09,978 --> 00:06:14,873
The history shows the synced fault and
status The desk check is separate

88
00:06:14,873 --> 00:06:19,563
don't issue while the item is blocked held
or otherwise ineligible

89
00:06:19,663 --> 00:06:24,388
Check the result Match the tag service
result resolved fault

90
00:06:24,388 --> 00:06:28,998
and readiness identifier If a confirmed
save is followed by a refresh

91
00:06:28,998 --> 00:06:32,873
failure refresh and read back before
acting again

92
00:06:32,973 --> 00:06:37,613
If something goes wrong Resolved is
unavailable or the desk still

93
00:06:37,613 --> 00:06:42,448
blocks reissue Check that the latest pass
was saved for this exact item

94
00:06:42,448 --> 00:06:47,288
refresh and look for other unresolved
faults or custody restrictions

95
00:06:47,288 --> 00:06:51,073
Keep the item out of use and ask your site
manager or in-app Help if the

96
00:06:51,073 --> 00:06:52,893
records disagree

97
00:06:53,017 --> 00:06:57,652
Record observed radio programming Write
down the configuration already

98
00:06:57,652 --> 00:07:01,542
observed on a radio without changing the
handset

99
00:07:01,642 --> 00:07:06,382
Step 1 In Site operations select
Programming then choose

100
00:07:06,382 --> 00:07:11,107
Radio and review Observed on the radio
before entering new observations

101
00:07:11,107 --> 00:07:15,772
You should see The tag and prior saved
values appear or the page says

102
00:07:15,772 --> 00:07:18,862
no programming observations are recorded

103
00:07:18,962 --> 00:07:23,757
Step 2 Under Record the actual
configuration enter Profile

104
00:07:23,757 --> 00:07:28,512
and Channels comma-separated as observed
Default channel

105
00:07:28,512 --> 00:07:33,372
must be blank or match one of those
channels Set Scan to Unknown

106
00:07:33,372 --> 00:07:38,167
Disabled or Enabled Enter Scan list
comma-separated

107
00:07:38,167 --> 00:07:43,092
only with Enabled another choice clears
the list You should see

108
00:07:43,092 --> 00:07:47,602
The form describes the settings you
observed on that radio A crew plan

109
00:07:47,602 --> 00:07:50,412
alone is not evidence of those settings

110
00:07:50,512 --> 00:07:55,092
Step 3 Select Save programming record
After

111
00:07:55,092 --> 00:07:59,352
confirmation reselect the same radio and
compare Observed on the radio

112
00:07:59,352 --> 00:08:03,892
with your observations You should see
Programming record saved

113
00:08:03,892 --> 00:08:08,407
confirms the record The saved values read
back without programming or

114
00:08:08,407 --> 00:08:10,277
testing the hardware

115
00:08:10,377 --> 00:08:15,382
Check the result Compare profile channels
default

116
00:08:15,382 --> 00:08:20,447
scan and scan list Workspace Equipment
also shows Recorded programming

117
00:08:20,447 --> 00:08:21,877
when synced

118
00:08:21,977 --> 00:08:26,612
If something goes wrong The default is
rejected or another observation was

119
00:08:26,612 --> 00:08:31,257
saved first Check the exact channel labels
After

120
00:08:31,257 --> 00:08:35,522
a conflict refresh and reselect the radio
then review the latest

121
00:08:35,522 --> 00:08:40,347
observation before saving Do not overwrite
it from memory or use a plan

122
00:08:40,347 --> 00:08:41,802
as evidence